Product

Off-grid HSI 5500P

Additional information

Model Name

HSI 5500P

Rated Output Power

5500VA

Rated Voltage

48V

PV

500V

AC

220/230V

Energy Efficiency

Up to 99.9% MPPT capture efficiency

Dimensions

426mm*322mm*126mm

Weight (KG)

10.5

Off-grid Solar Inverter

HSI 5500P (PV:500V;AC:220/230V)

 

Performance characteristics

 

  • Load friendly: Stable sine wave AC output via SPWM modulation
  • Supports a wide range of battery technology: GEL, AGM, Flooded, LFP, and program.
  • Dual LFP battery activation method: PV&mains
  • Uninterrupted power supply: simultaneous connection to utility grid/generator and PV .
  • Intelligent programming: the priority of the output from different energy sources can be set.
  • High energy efficiency: up to 99.9% MPPT capture efficiency.
  • Instant viewing of operation: the LCD panel displays data and settings ,while you can also be viewed using the app and webpage.
  • Power saving: power saving mode automatically reduces power consumption at zero-load.
  • Efficient heat dissipation: via intelligent adjustable speed fans
  • Multiple safety protection functions: short circuit protection, overload protection, reverse olarity protection, and so on.
  • under-voltage and over-voltage protection and reverse polarity protection.
  • Supports up to 6 devices of the same model connected in parallel
  • (forming a single-phase,split-phase,three-phase electrical system)

 

Product characteristics

 

 

Parameters

 

Model HSI 5500P Adjustable
Battery Input
Battery type Sealed、FLood、GEL、LFP、Ternary
Rated Battery Input Voltage 48V ( Minimum Startup Voltage 44V)
Hybrid Charging Maximum

Charging Current

80A
Battery Voltage Range 40Vdc~60Vdc ± 0.6Vdc(Undervoltage Warning/Shutdown Voltage/ Overvoltage Warning/Overvoltage Recovery…)
Solar Input
Maximum PV Open-circuit Voltage 500Vdc
PV Working Voltage Range 120-500Vdc
MPPT Voltage Range 120-450Vdc
Maximum PV Input Current 22A
Maximum PV Input Power 6000W
Maximum PV Charging Current 80A
AC Input(generator/grid)
Mains Maximum Charging Current 60A
Rated Input Voltage 220/230Vac
Input Voltage Range UPS Mains Mode:(170Vac~280Vac)土2% APL Generator Mode:(90Vac~280Vac)±2%
Frequency 50Hz/ 60Hz (Automatic Detection)
Mains Charging Efficiency >95%
Switch Time (bypass and inverter) 10ms(Typical Value)
Maximum Bypass Overload Current 40A
AC Output
Output Voltage Waveform Pure Sine Wave
Rated Output Voltage (Vac) 230Vac
Rated Output Power (VA) 5500
Rated Output Power(W) 5500
Peak Power 11000VA
On-load Motor Capacity 4HP
Output Frequency Range(Hz) 50Hz±0.3Hz/60Hz±0.3Hz
Maximum Efficiency >92%
No-load Loss Non Energy-saving Mode: ≤50W Energy-saving Mode:≤25W (Manual Setup)
General
Number of parallel/split phases 1-6PCS
Certificate CE(IEC62109-1)/CETL(UL   1741   C22.2   NO.107.1)/FCC/SAA
EMC Certification Level EN61000, C2
Working Temperature Range -10°C ~ 55°C
Storage Temperature Range -25°C ~ 60°C
Humidity Range 5% to 95%(Conformal Coating Protection)
Dimensions 426mm*322mm*124mm
Weight (KG) 10.5