Model Name

HSI 3500

Rated Output Power

3500VA

Rated Voltage

24V

PV

500V

AC

220/230V

Battery Type

Sealed、FLood、GEL、LFP、Ternary

Energy Efficiency

Up to 99.9% MPPT capture efficiency

Dimensions

378mm*280mm*103mm

Weight (KG)

7.4

Off-grid Solar Inverter

HSI 3500 (PV:500V;AC:220/230V)

 

Performance characteristics

 

 

  • Load friendly: Stable sine wave AC output via SPWM modulation
  • Supports a wide range of battery technology: GEL, AGM, Flooded, LFP, and program.
  • Dual LFP battery activation method: PV&mains.
  • Uninterrupted power supply: simultaneous connection to utility grid/generator and PV.
  • Intelligent programming: the priority of the output from different energy sources can be set.
  • High energy efficiency: up to 99.9% MPPT capture efficiency.
  • Instant viewing of operation: the LCD panel displays data and settings ,while you can also
    be viewed using the app and webpage.
  • Power saving: power saving mode automatically reduces power consumption at zero-load
  • Efficient heat dissipation: via intelligent adjustable speed fans.
  • Multiple safety protection functions: short circuit protection, overload protection, reverse
    polarity protection, and so on.
  • under-voltage and over-voltage protection and reverse polarity protection.

 

Product Characteristics

 

 

Parameters

 

 

Model HSI 3500 Adjustable
Battery Input
Battery type Sealed、FLood、GEL、LFP、Ternary
Rated Battery Input Voltage 24V ( Minimum Startup Voltage 22V)
Hybrid Charging Maxi

mum Charging Current

80A  

Battery Voltage Range 20Vdc~33Vdc ± 0.3Vdc(Undervoltage Warning/Shutdown Voltage/Overvoltage Warning/Overvoltage Recovery…)  

Solar Input
Maximum PV Open-circuit

Voltage

 

500Vdc

PV Working Voltage Range 120-500Vdc
MPPT Voltage Range 120-450Vdc
Maximum PV Input Current 13A
Maximum PV Input Power 4000W
Maximum PV Charging Current 80A
AC Inputgenerator/grid
Mains Maximum Charging

Current

 

80A

Rated Input Voltage 220/230Vac
Input Voltage Range UPS Mains Mode:(170Vac~280Vac)土2% APL Generator Mode:(90Vac-280Vac)±2%
Frequency 50Hz/ 60Hz (Automatic Detection)
Mains Charging Efficiency >95%
Switch Time (bypass and inverter) 10ms(Typical Value)
Maximum Bypass Overload Current 30A
AC Output
Output Voltage Waveform Pure Sine Wave
Rated Output Voltage (Vac) 230Vac
Rated Output Power (VA) 3500
Rated Output Power(W) 3500
Peak Power 6000VA
On-load Motor Capacity 2HP
Output Frequency Range(Hz) 50Hz土0.3Hz/60Hz±0.3Hz
Maximum Efficiency >92%
No-load Loss Non Energy-saving Mode: ≤50W Energy-saving Mode:≤25W (Manual Setup)
General
Certificate CE(IEC 62109-1)/FCC/SAA
EMC Certification Level EN61000, C2
Working Temperature Range -10°C ~ 55°C
Storage Temperature Range -25°C ~ 60°C
Humidity Range 5% to 95%(Conformal Coating Protection)
Dimensions 378mm*280mm*103mm
Weight (KG) 7.4

 

 

 